If FAFNIR module in SK700 has fixed critical amount of errors of GRF, the further work will be impossible. There is way to correct this problem. It's necessary to connect the signal wire SA and SB from module FAFNIR on GND.
Variant 1:
In Head on block FAFNIR we disconnect the white wire and connect to nearby brown together (white - SA, brown - GND). Also we do with gray and orange (gray - SB, orange - GND).
Variant 2:
On Board GRF-Interface (it's under table near by IS-Interface) we connect contacts 1 and 2 (SA and GND), and contacts 5 and 6 (SB and GND) with short wire. White and gray wire to disconnect and cut.
Продаю новые и б/у запчасти к ТРК Gilbarco Veeder Root Wayne Dresser Scheidt & Bachmann Schlumberger Tokheim - электронику, механику, шланги, расходные материалы. Skype: kibhome e-mail: pumpcrash@gmail.com
Tuesday, February 5, 2008
Monday, February 4, 2008
SK700 Gilbarco Veeder-Root totalizer erase crash
In Gilbarco Veeder-Root SK700 possible elementary to clean the totalizator. In head disconnect output connector from filter. Sandpiper begins to write into memory last data of totalizer, before this cleans old. All are other parameters and adjustment do not change. For writing new data it is not enough energy of the small capacitor on Sandpiper. The Main capacitors remained in filter. If there is access to security jumper, possible install new data.